Hydroponics Online Store



Hydroponic Systems

Hydroponic Grow Lights & Bulbs

Hydroponic Tents & Grow Boxes

Hydroponic Ballasts

Grow Light Reflectors

Hydroponic Nutrients

Grow Media Rocks

Hydroponic Pumps

Hydroponic Pots

Hydroponic Books

Meters

Hydroponic Exhaust Fans

Hydroponic Seeds

Hydroponic Foggers

Home Store Blog Forums FAQs Lesson Plans Pictures


Search:



MLC HID Light Control Box 120V 4KW/240V 8KW 8 Outlet Hydroponic+Trigger Cord For Sale


MLC HID Light Control Box 120V 4KW/240V 8KW 8 Outlet Hydroponic+Trigger Cord
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.



Buy Now

MLC HID Light Control Box 120V 4KW/240V 8KW 8 Outlet Hydroponic+Trigger Cord:
$66.50

  • + ChromePlacement on Vehicle:Front, UpperFitment Type:Direct ReplacementType:GrilleInstallation Instructions:Not includedBrand: Unbranded Product function description:NOTE:Installation Manual Is NOT Included Professional Installation Is Highly Recommended Features :• Controls up to four or eight 1000W high intensity discharge (HID) ballasts, includingboth metal halide (MH) and high pressure sodium (HPS) lighting systems. • Integrated 120V trigger cable facilitates any timed lighting sequence whenconnected to a standard 24-hour timing device• Green LED indicator illuminates when light controller. is activated and ON via thetrigger cable function. • Composed of high-quality components for reliable, long-term performance.
    MLC HID Light Control Box 120V 4KW/240V 8KW 8 Outlet Hydroponic+Trigger Cord8 Outlet 120V/240v 50Amp MLC Electric Box HID Master Light Timer Controller W/trigger cordProduct function description:NOTE:Installation Manual Is NOT IncludedProfessional Installation Is Highly Recommended

    Features:

    • Controls up to four or eight 1000W high intensity discharge (HID) ballasts, including

    both metal halide (MH) and high pressure sodium (HPS) lighting systems.

    • Integrated 120V trigger cable facilitates any timed lighting sequence when

    connected to a standard 24-hour timing device

    • Green LED indicator illuminates when light controller. is activated and ON via the

    trigger cable function.

    • Composed of high-quality components for reliable, long-term performance.

    • Wall-mountable.

    SPECIFICATIONS:

    Main Power Voltage: 120V OR 240V

    Receptacle Type: 8 Universal Outlets

    120V Max Wattage: 4000W total

    240V Max Wattage: 8000W total/1000W per Outlet

    Max Amperage: 50A

    Trigger Cable Voltage: 120V

    Operating Temperature Range: 32-110°F

    Operating Humidity Range: 0-99% RH Noncondensing

    Minimum Relay Operations: 100,000 @ Full Load

    Important Precautions :

    • Consult a licensed electrician prior to installation or have the unit professionally installed.

    • DO NOT install the Light Controller if you are unfamiliar with electrical wiring and

    circuits OR if you do not fully understand the instructions.

    • All local and national electrical codes MUST be followed.

    • Use the Light Controller ONLY for its intended purpose.

    • DO NOT exceed the maximum ratings of this unit.

    • Verify all devices to be controlled by the Light Controller are of the correct voltage.

    • Unit is for indoor use only. Exercise extreme caution in moist or humid

    environments.

    • Improper installation or use of this controller could result in severe damage and/or

    personal injury.

    Main Power Requirements :

    A main power source must be supplied for the lights to function.

    • Verify main power source has the same voltage and amperage ratings as the

    equipment being controlled by the Light Controller (see specifications above).

    • Main power can be hardwired to a circuit breaker panel or installed using the

    appropriate high-amperage portable cable and connector end (not included).

    • 8 Outlets Light Controller, Use only a 50A, 2-pole circuit breaker and #6 AWG wire to provide the main power.

    • Proper connection of the ground wire to the ground lug is critical for safe operation.

    • All connected ballasts MUST BE wired correctly and according to the main power voltage.

    *The Light Controller with universal 120/240V receptacles can be used to

    operate 120V devices ONLY IF the main power is also wired in at 120V.

    Connecting a 120V ballast to a controller with 240V main power could result

    in damage or fire.

    Notice:

    * 240V main power requires ballasts wired for 240V (most common application).

    * 120V main power requires ballasts wired for 120V.

    Installation Notice:

    DO NOT connect ballasts to the Light Controller until AFTER the main power has been

    properly installed.

    Verify trigger cable is disconnected from the external timer or controller.

    Connect ballast power cables to the receptacles on the Light Controller.

    Connect the trigger cable to the external timer or controller.

    Main Power Connection :

    • Use a screwdriver to remove each of the four screws securing the front cover to the

    back casing.

    • Feed the properly rated main power cable into the cable clamp and tighten the

    clamp to secure the cable in place.

    • Insert the green or bare ground wire into the grounding terminal and secure.

    • Strip the insulation from the main power wires. Insert and tighten each bare wire

    end into the 2 power connection points on the power relay (L1 and L2 shown above

    picture). Secure the wires tightly to ensure a good connection. Loose connections will

    cause the terminals on the relay to overheat which can cause damage to the unit that

    is NOT covered by the warranty.

    • Turn on the circuit breaker or connect the main power cable connection. The Light

    Controller will now be powered.

    • Use a voltage meter to verify correct voltage BEFORE plugging ballasts into the

    Light Controller. If connected to a 240V circuit, the voltage meter should read

    approximately 240V. If connected to a 120V circuit, the voltage meter should read

    approximately 120V.

    • Once all voltage has been verified, carefully reinstall the front cover.

    Trigger Cable Testing :

    • 120V trigger cable MUST be connected to an external timing device or controller

    providing 120V to the main relay.

    • Main relay will close when the trigger cable is connected and activated, producing a

    distinct click.

    • When the trigger cable is plugged in to an external device and the externally

    connected timer/controller is ON, the green LED indicator light will illuminate.

    • When the trigger cable is disconnected from the external timer/controller, the green

    LED indicator light will turn off.

    • Unplug the trigger cable from the external timer/controller after it has been tested

    for proper operation.

    Controlling a Light Bank:

    Package includes:

    · 1 XLight Control Box(As picture)PaymentDelivery detailsTerms of salesAbout usContact usPaymentWe accept payment 。Fees such as import duties, taxes are not included in the item price or shipping costs. These charges are the buyer\'s responsibility.Delivery detailsShipping:2-9 working days to: USATerms of sales
      • We maintain high standards of excellence and strive for hundred percent customer satisfaction. response is very important to us. We hope that you contact us immediately before you give neutral or negative response, so that we can address your concerns. It is impossible to address issues if we do not know about them!
    About usYour satisfaction is our ultimate goal. We work hard to earn your trust and future business. Our certified technicians have tested each item before shipping. The unit comes with 1 year limited warranty on all manufacturing defects.a) If you receive a defective item, you may return it or ask for a discount. Please contact us within 14 days after you receive the package.b) What you returned must be intact and in its original packaging as re? u. Customer is responsible for shipping costs of the returned item.c) We will cover the cost of shipping back t with the shipping rate indicated in the registration page. We will send you a new unit or refund the full payment you paid.Thank you.Contact usBusiness Hour Business Hour: Monday To Friday: 8:30 AM to 5:00 PM (Beijing China time)Due to time zones, our reply to your questions may not be immediately. But within above working time, we will reply your email within 24 hours. If it\'s non-workdays, please kindly be patient and wait till Monday.Please contact us with message.Please feel free to contact us if you have any questions. Monday To Friday: 8:30 AM to 5:00 PM (Beijing China time)Due to time zones, our reply to your questions may not be immediately. But within above working time, we will reply your email within 24 hours. If it\'s non-workdays, please kindly be patient and wait till Monday.Please contact us with message.Please feel free to contact us if you have any questions.

    Buy Now


 

Hydroponic Forum Discussions:


Popular Hydroponic Items: